Would it be just a resistor thats moved out of spec? - DC amps: none of the ranges seem to work and I have no idea why. DC volts range: What am I looking for to determine why its reading low? it seems to read low by about the same amount on all the DC volts ranges. Advice I like: - I'm not so crash hot with analog electronics like this so feel free to pretend I'm an idiot when it comes to this. But of course I will if theres no other way to repair it. UNIVERSAL AVOMETER GOERZ Unigor 6e P: UNIVERSAL MULTIMETER UM-11: UNIVERSAL AVOMETER ERREPI A.V.O. I'm hesitant to disasemble the boards from each other, since it requires desoldering a number of components. Re: Show your Multimeter Reply 898 on: September 13, 2018, 08:11:08 am Aaaand.not a new multimeter, but I have finally managed to aquire the original Goerz RF probe for use with the Unigor 6e. Semiconductors Wave bands - without Power type and voltage Dry Batteries / 4 × 1,5 Volt Loudspeaker - No sound reproduction output. Technical Specifications Number of Transistors Semiconductors present. According to the schematic, theres at least a couple diodes and caps, but I haven't been able to find them on the device yet. Unigor 6eP 226236.74 (1) Click on the schematic thumbnail to request the schematic as a free document. I've tested only a few dozen of the components, the ones I can easily access, and they all seem to be working and reading correctly. I can't see any components that are obviously damaged, though many are discoloured from age.

goerz unigor 6e manual

Theres some corrosion from a dead battery that needs cleaning, but beyond that I'm not sure where to start on diagnosing this. I haven't tried AC yet for fear for frying it. The Amps and Ohms ranges don't seem to work at all. Where I'm at: - Currently only the DC voltage range is working, and even then not very accuratly, reading about 10% below true. The company that made it, Goerz Electro, was Austrian, founded in 1907 and originally made optical assemblies, then later electronic test equipment.

GOERZ UNIGOR 6E MANUAL MANUAL

The only info I can find about the meter is from this page: - The meter comes with a very cute manual booklet meant to look like the device itself.

GOERZ UNIGOR 6E MANUAL PLUS

Plus I think this thing just looks really cool, and I want to see how it compares to my modern DMMs. Background: - The multimeter belongs to my girlfriends dad, and I'm wanting to fix it as a gift for him. The Unigor 6E is an electronic multimeter, meaning it has a built-in battery-operated transistor. Die Geräte der Serie UNIGOR n entsprechen den höchsten Ansprüchen auf dem Gebiet der analogen Vielfach-Meßgeräte. Unigor by Goertz was a brand of robust meters from Austria.

GOERZ UNIGOR 6E MANUAL MANUALS

Page generated on: © 2004-2017 Edward Kujawski This page took 0.036 seconds to render.Hi Guys, I have a Goerz Unigor model 1 multimeter that I'm trying to restore to working order. If you have any other manuals for the Goerz Electro Unigor 3N you can upload the files here. Question Bank with chapter wise questions 3. Or, you can email me directly with the manual. Contact Information: Submitting a Manual If you have a better copy of any of these manuals or a manual which is not listed, and wish to share, you can upload the manual to.

GOERZ UNIGOR 6E MANUAL DOWNLOAD

These manuals are available for download and free of charge.Īdvertisement Viewers: These viewers may be required to view the manuals on this archive: If anyone knows of additional suitable GIF/JPEG viewers that are free to use, email me and I will include a link. If you are not familiar with electronics, do not attempt to repair! Whether you suffer fatal electrical shock! Instead, contact the nearest service center! Category METER USERMANUAL(HU) Sponsored link. Wide, The approach zone expands outxard unifor~ly t o a width of 4,000 feet at, a. Budget of one accident in 10 mitiion approaches 6.e. This part of the Airport Services Manual includes guidance on the.